AED Cuhd1 standard package 3 lead ECG ;external paddles ; printer ; carry case

Brand: BizzMed Category: Tag:

R0.00 Vat Inclusive

(0 reviews)

1. Product overview

LifeGain CU-HD1 – this is the company’s high end defibrillator/monitor intended for hospital use. It has defibrillation capabilities in AED and manual modes and may use disposable electrode pads and external and internal paddles for shock delivery. It has a transcutaneous pacer for temporary pacing of patients with low heart rate. It has an SPO2 module for the monitoring of oxygen saturation in the patient’s blood and a 12-lead ECG monitor for the evaluation and monitoring of the patient’s ECG.

It has a memory card port for the storage of acquired signals and an integrated printer for the generation of hard copies of the patient’s physiological signals. These features make this defibrillator suitable for use inside a hospital.This product is a defibrillator designed for qualified emergency staff and medical professionals to deliver defibrillating shocks to victims of sudden cardiac arrest and restore the normal ECG rhythm.

Out of stock

Description

* AED Mode

AED Mode is delivered to patients who are exhibiting the symptoms of Sudden Cardiac Arrest (SCA) including ventricular fibrillation, ventricular tachycardia, in order to bring them back to life by delivering electric shock and restoring the normal ECG rhythm.

In the AED mode, defibrillation pads must be used. These defibrillation pads work to obtain the ECG signal of patients and deliver electric shock according to the patients’ condition.

* Manual Mode

Manual Mode is divided into two functions such as asynchronous defibrillation and synchronous cardioversion. In asynchronous defibrillation, the usage target is the same in AED Mode.

For the asynchronous defibrillation treatment in the manual mode, the user is able to choose the level of electric shock energy from the range of 1-200 joule by the use of pads or paddles.

On the other side, when used for synchronous cardioversion, it is used on patients with the symptoms of atrial fibrillation. It is designed to analyze the R-wave of ECG QRS and deliver R-wave synchronized electric shocks.

In the Manual mode, synchronous cardioversion treatment can be delivered to patients with rapid atrial fibrillation, ventricular tachycardia, and cardiac ischemia.

* Pacer Mode

Pacing is a method applied to patients who had lost natural cardiac movement functions, mostly used on patients with bradycardia. LiFEGAIN CU-HD1 functions to support non-invasive pacing, a way of helping maintain a patient’s pulse by attaching its electrode to the patient’s skin and delivering artificial electric stimulation to the heart. Pacing mode is divided into the ‘Fixed mode’ and the ‘Demand mode’.

* Monitoring Mode

Patient monitoring mode features the ECG monitoring function and the function to measure the level of SpO2, functional oxygen saturation in the blood.

For the ECG monitoring function, you can discriminatingly use the 3-lead, 5-lead, 12-lead ECG cables. During the patient monitoring session, it is possible to analyze the ECG results to use the alarming function according to the conditions such as the number of pulses, ventricular fibrillation or ventricular tachycardia etc. If using an ECG cable, convert “Rotary Switch” to “Monitor mode” before usage.

* Key features

Manual and AED Operation
Defibrillation using paddles or pads
Synchronized cardioversion
Efficient and effective e-cube Biphasic technology (BTE Type)
SpO2 pulse oximetry with alarm
ECG monitoring (3 Lead ECG / 5 Lead ECG / 10 Lead ECG)
Noninvasive pacing mode
Specification

Model Name
Item Description
Lifegain CU-HD1
Defibrillator / Monitor
Parameter Description
Specified
DEFIBRILLATOR
Operating Modes Manual / Semi automatic
Waveform Biphasic (Truncated exponential type)
Shock Delivery Via Paddles or multi-function defibrillator electrode pads
Reusable External Paddle Yes
Pediatric Paddle Yes
Multifunction Defi Pads (Disposable) Yes
Energy sequence Yes
Manual mode, J 1~10, 15, 20, 30, 50, 70, 100, 120, 150, 170, 200 J
Synchronous Cardioversion Yes
AED mode, J Fixed energy at 200 Joules
Text and Voice Prompts Yes
Protocol configured Yes
ECG MONITOR
ECG acquisition Disposable electrodes
Monitors with ECG YES
Input Lead I, II, III (3 Lead ECG cable)
Lead I, II, III, aVR, aVL, aVF or V (5 Lead ECG cable)
Lead I, II, III, aVR, aVL, aVF or V1, V2, V3, V4, V5, V6 (10 Lead ECG cable)
(Display View : All 12 Lead ECG waves display simultaneously)
Electrodes Yes
ECG display Yes
Message display Yes
Heart rate display 30 to 300 bpm (±3bpm)
ECG size 5, 10, 20mm/mV and Auto-gain
Heart Rate/Arrhythmia Alarm HR, Asystole, VF, VT
Lead Fault message Yes
NONINVASIVE PACING
Waveform Monophasic Truncated Exponential
Mode Demand and Fixed mode
Amplitude Accuracy 0 ~ 200mA (±5mA)
Pulse Width 20ms (±1.5%)
Pulse Rate 30 ~ 180ppm (±1.5%)
Refractory Period 340 msec (30 to 80ppm) / 240 msec (90 to 180 ppm)
SpO2 Pulse Oximetry
SpO2 monitoring Yes (Nellcor)
Saturation 70~100% (±3digits)
Pulse Rate 20~250bpm (±3bpm)
Perfusion 0.2%
SpO2 alarm YES (Less than minimum setting rate, Over than maximum setting rate)
NIBP
Patient Population Adult, Pediatric, Neonate
Method Oscillometric
Control Autometic and manual measurements
Auto Intervals 1, 3, 5, 10, 15, 30, 60, 120 min
Displayed Pressures Systolic, Diastolic, Mean mmHg
Displayer Units Adult : 40 to 260 mmHg
Pediatric : 40 to 160 mmHg
Neonate : 40 to 130 mmHg
Systolic Range Adult : 20 to 200 mmHg
Pediatric : 20 to 120 mmHg
Neonate : 20 to 100 mmHg
Diastolic Range ±3mmHg
Pressure Trransducer Accuracy Adult : 300 mmHg / Pediatric 300 mmHg / Neonate : 150 mmHg
Redundant Circuit Overpressure Limit
PRINTER
Continuous ECG Strip Real-Time (8 seconds delay)
Auto Printing Recorder can be configured to print marked event, charge, shock and alarms
Printing Speed 25mm/s
Paper 50mm Width / 40mm Diameters
DATA STORAGE
Information stored ECG data, Event, Voice
Internal memory Yes
Even & ECG record Yes
Database storage Yes
External memory card Yes(SD card)
EXTERNAL LINK
Data management Yes
Software Yes(CU-Expert)
POWER SOURCE
Type Lithium Polymer (14.8V 3.1Ah – Rechargeable)
Integral/removable Removable
Charging method AC adapter / Car Cigar Lighter Jack / both
AC Power Pack Output : 18V, 6A
PHYSICAL
Size 318 X 208 X 355 (W X L X H, mm)
Weight 5kg (with external paddle)
DISPLAY
Type TFT Color
Size 7 inch Diagonal (152mm X 91mm)
Resolution 800 X 480 pixels
AUTOMATIC SELF-TEST
Power on Self-Test YES
Run Time Self-Test YES
Manual Self-Test YES
Periodic Self-Test Daily / Weekly / Monthly

0.0 Average Rating Rated (0 Reviews)

Rated
0%
Rated
0%
Rated
0%
Rated
0%
Rated
0%

Be the first to review “AED Cuhd1 standard package 3 lead ECG ;external paddles ; printer ; carry case”

Your email address will not be published. Required fields are marked *

You have to login to add images.

BiancaNo ratings found yet!
  • Store Name: BizzMed
Visit Store

Product Enquiry

Please Login to make enquiry about this product
More Products